Caution!
Do not use more than one of the three
sets of jumper pins simultaneously.
The relay output rating on this Unit is
25A max output. Defective OEM
solenoid switches can sometimes draw
up to 50 or 60A, causing the 30A fuse
to blow. Using a digital voltmeter, check
the Starter wire for amperage when
vehicle is cranking.
Ignition-Controlled Door Locks
x Ignition Lock disabled: turns OFF the Ignition Lock feature.
x Ignition Lock enabled: locks all Doors when the key is in the ON position and the user
presses the Brake Pedal. Similarly, when the Ignition key is turned to the OFF position,
the Doors will unlock.
x Ignition Lock Only: the system will only lock all Doors when the Ignition Key is turned
to the IGNITION ON (RUN) position and Brake Pedal is pressed.
x Ignition Unlock Only: the system will unlock all Doors when the Key is turned to the
OFF position, provided the Ignition Key was in the IGNITION ON (RUN) position and the
Brake Pedal was pressed at least once.
Table 7
Secure Lock
(OFF by default.)
For vehicles where the OEM Alarm can be controlled the through the OEM
LOCK and UNLOCK
wires, Secure Lock saves the installer from connecting the ARM and DISARM wires and the
LOCK and UNLOCK wires to the OEM LOCK and UNLOCK wires.
Upon receiving a remote start signal the system will unlock the Doors (disarming the OEM
Alarm); 1/2 sec after the remote start, the system will
LOCK the Doors.
Please note: most factory Alarm systems will not rearm while the Engine is running but will
lock the Doors.
4 seconds after the Module shuts off (i.e.: runtime expired or pressing the
STOP button),
Secure Lock will
LOCK (once more) all the Doors of the vehicle and REARM the OEM Alarm.
Smart Secure Lock operates as follows:
x If the Alarm is armed and the Starter Kill is armed, a remote start signal will be
accompanied by an UNLOCK and a DISARM pulse preceding start-up. The system will LOCK and
arm again once the Engine is running.
x If the Vehicle is initially unlocked, a remote start signal will start the Engine and enable
the Starter Kill without unlocking or locking the Doors.
Table 8
Turbo Mode
This Option allows turbochargers to idle down: after the user leaves the vehicle, the Engine
will keep running for 60 sec. and then shut down (It is a 1-minute Idle Mode).