Audiovox PRO 9644 Remote Starter User Manual


 
Page 7
4. Within 10 seconds, begin to enter your chosen 10ths digit by pressing and releasing the
pushbutton switch from 1 up to 9 times.
5. Within 10 seconds of the last entered 10ths digit, turn the ignition switch off then on.
6. Within 10 seconds, begin to enter your chosen units digit by pressing and releasing the
pushbutton switch from 1 up to 9 times.
7. Finish by turning the ignition switch to the off position.
If the new code was accepted, the unit will report back the newly entered code, by flashing
the LED, first indicating the 10ths digit, pause and then the units digit. The unit will report the
new code three times with a one second pause between each code, then the system will
begin arming. If the LED flash pattern reports the previously stored code, the new code was
not entered correctly. Please repeat steps 1 through 7 above considering the following.
NOTE: Acceptable digits 10ths or units are 1 through 9. The unit will not recognize a 0
(Zero), or no digit entered in any place, units or tenths.
NOTE: If 15 seconds of in activity expire, or if the ignition switch is turned off for more than
5 seconds during any of the above steps, the unit will revert back to the last
successfully stored code.
Custom Code Programming Example:
To Change the code from the factory pre-assigned code of 11 to "52" you would do the
following:
1. Disarm the system by use of the transmitter, or by use of the emergency override se-
quence.
2. Turn the ignition switch to the on position.
3. Within 10 seconds, press and release the valet/override switch, 3 times.
4. Within 10 seconds turn the ignition switch off, on, off, on, off, on. (The siren or horn will
beep and the lights will flash one time.)
5. Within 10 seconds, begin to press and release the push button switch to set the tenths
digit. (As per the example, press and release 5 times to set the tenths digit to 5)
6. Within 10 seconds of the last press of the push-button, turn the ignition switch off then
on.
7. Within 10 seconds, begin to press and release the push button switch to set the units
digit. (As per the example, press and release 2 times to set the units digit to 2).
8. Turn the ignition switch to the off position. Immediately observe the LED flash pattern.
You will note the LED flashing five times, pause, and then flash two times, pause. This
pattern will be repeated three times indicating the new code (52) has been accepted and
stored in memory.
NOTE: If after step 7, the LED flashes a code other than what was just entered, this
indicates that the code has not been changed. You will have to repeat steps 1
through 7 above being certain to note the following:
Acceptable digits 10ths or units are 1 through 9. The unit will not recognize a 0 (Zero), or no
digit entered in any place, units or tenths.
NOTE: If 15 seconds of inactivity expire, or if the ignition switch is turned off for more then
5 seconds during any of the above steps, the unit will revert back to the last
successfully stored code.