Audiovox APS-995C Remote Starter User Manual


 
R F SHOCK SENSOR MODE SELECTION
The way in which your alarm system reacts to threatening vibrations, created by
attempts to enter the vehicle by breaking a window, is adjustable by the transmitter
immediately after arming. There are 4 modes of operation that can be selected
by the operator:
1. Normal Operation (default mode)
In this mode, any strong vibrations will cause the siren to sound (full
detect) for 30 seconds. Any lesser vibration will cause the siren to emit about
6 short warn away chirps, (pre-detect).
2. Stage 1 (Omit pre-detect)
In this mode, the warn away chirps created by the lesser vibration will be
deleted. If strong vibration occurs, the siren will sound.
3. Stage 2 (Omit pre & full detect)
In this mode, both the pre-detect stage and the full trigger stage of the sensor
are defeated. The unit will not react to vibration of any magnitude.
NOTE: Shock Sensor Icon Is Displayed On The LCD Panel.
4. Stage 3 (City Mode)
In this mode, the pre-detect chirps will change from six pre-warning tones to
a full 10 seconds of warning chirps.
The full detect trigger duration will be reduced from 30 seconds to 15 seconds.
NOTE: Setting the stage of the shock sensor will be effective for one arming cycle
only. Once the system has been disarmed, the very next arming cycle will
cause the sensor to default to the normal operation stage.
To change or adjust the shock sensor, press and release the ARM button of you
keychain transmitter.
1.Within 2 seconds of arming, press and release the ARM button 1 time, to
defeat the pre-detect stage of the shock sensor. (The lights will flash and the
siren will chirp once.)
2.Within 2 seconds of step 1, press and release the ARM button 2 times, to
defeat the pre and full detect stages of the shock sensor. (The lights will
flash and the siren will chirp twice.)
3.Within 2 seconds of step 1, press and release the ARM button 3 times to
enter the "City Mode" of operation. (The lights will flash and the siren will chirp
three times.)
SAFETY (Red Handled ) CONTROL SWITCH
The control switch allows you to temporarily disable the remote starting function
of your APS-995C. To disable the unit, move the red handled control switch to the
off position.
The control switch also allows you to select between 2 hour start up and 4 hour
start up when using the automatic start up timer mode. The factory preset start up
time for this mode is every 4 hours. To select between 2 or 4 hour start-up timer:
1. Begin with the control switch in the on position.
2. Turn the ignition switch on then off.
Page 10