Ultra Start 1150 Series Remote Starter User Manual


 
Page 4
INSTALLATION MANUAL
REMOTE VEHICLE STARTER
Yellow Starter 30amp output 12volts during crank only.
Green Heater 30amp output 12volts in accessory off during start.
Red 12 power 30amp input Constant 12volt power at ignition harness.
Red 12 power 30amp input Constant 12volt power at ignition harness.
Blue Ignition 1 30amp output 12volts in ignition and start positions.
White Select Output 30amp output Selectable Output. See jumper diagram.
Yellow Re-Arm 0.75sec Pulse On Shutdown. (500ma Output)
Red/White N/A Not Used on this model.
Brown Disarm 0.75sec Pulse With Unlock And Before Start.(500ma Output)
Orange (-) Output (-) While Running
White/Blue Horn (-) Horn Honk Output
Black/White N/A Not Used on this model.
Purple (+) Start Connect to positive start input.
White Park Lights Positive Park light Output - 10 Amp Max.
Green/White Hood Pin Negative Hood Pin Input - MUST BE CONNECTED!!
Green (-) Start Connect to negative start input.
Black Ground System Ground Input - MUST BE CONNECTED!!
Pink Brake Positive Brake Input - MUST BE CONNECTED!!
Blue/White Tach Tach Signal Input - Must be connected for Tach Mode!!
Blue Glow Plug Programmable Input - DIESEL ONLY.
Note: 500ma outputs are low current and are designed to activate relays.
* Connect only one start input. The start input will require 3 negative pulses within 2 seconds
To activate the remote starter.
6 Pin Power Connector
14 Pin Connector
4 Pin Connector Blue - Program LED/ Switch
Jumper Selections
Program LED/Switch connector. The program switch is integrated into the LED. Press the LED to
activate the switch.
Position One Second Starter Output On the White Wire From The 6-Pin Connector.
Position Two Second Accessory Output On The White Wire From The 6-Pin Connector.
*Position Three Second Ignition Output On The White Wire From The 6-Pin Connector.
* The Default Setting For The System Is Second Ignition Output.
The jumpers control the output from the white wire at the 6-pin harness. Place the jumper in the following
positions to change the output.
Note: The default jumper setting is second ignition.
Output on White wire Jumper position
Second Starter Position 1
Second Accessory Position 2
Second Ignition Position 3
WIRING CONNECTIONS