STEAM
F-37463 (09/10)
CEM6U
ELECTRIC COMBI OVEN
NOTE: In line with its policy to continually improve its products, Vulcan reserves the right to change materials and specications without notice.
WATER QUALITY STATEMENT
The fact that a water supply is potable is no guarantee that it is
suitable for steam generation. Your water supply must be within these
general guidelines:
SUPPLY PRESSURE 20 - 60 psig
HARDNESS* less than 3 grains
SILICA less than 30 ppm
TOTAL CHLORIDE less than 4.0 ppm
CHLORINE & CHLORAMINES 0 ppm
pH RANGE 7-8
UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount
of chlorination and dissolved gases. Water supplies vary from state
to state and from locations within a state. Therefore it is necessary
that the local water treatment specialist be consulted before the
installation of any steam generating equipment.
CLEARANCES
Rear - 6", Left Side - 2", Right Side - 6"
Allow for sufcient distance if a “high heat source” (i.e. Broiler) is •
located next to the unit.
Allow for sufcient clearance on right side for service access •
(contact the factory service department for recommendations).
Installation must comply with all local re and health codes.•
ELECTRICAL RATING
208V/60/3 240V/60/3
KW AMP KW AMP
9 26 10 25
PAN CAPACITY
STEAM TABLE PANS BAKE PANS
12" x 20" x 2
1
⁄
2
" 12" x 20" x 4" 18" x 13" 18" x 26"
6 3 6 N/A
SERVICE CONNECTIONS
E Electric connection: Single point supply 2" (51 mm) dia.
(
3
⁄
4
" - 19 mm strain relief).
C1 Cold water connection:
3
⁄
4
" NSHT for generator feed. Inlet
water pressure between 20 and 60 psi (138-414 kPa).
C2 Cold water connection:
3
⁄
4
" NSHT for cold water condenser.
Inlet water pressure between 20 and 60 psi (138-414 kPa).
D Drain: Condensate box, compartment and boiler 1
1
⁄
2
" NPT.
(Provide an open air type drain within 12" of condensate box
and for best results at a distance so that steam vapors will not
enter the steamer from underneath the control area. Do not
connect solidly to any drain connection.)
NOTE
Dimensions which locate the above connections have a tolerance •
of + or -3" (+ or -75 mm).
Installation of backow preventers, vacuum breakers and other •
specic code requirements is the responsibility of the owner
and installer. It is the responsibility of the owner and installer to
comply with local codes.
Do not use plastic drains. •
This appliance is manufactured for commercial installation only •
and is not intended for home use.