Primary lithium batteries
Li-SOCI
2
range
LS 14250 F
1
⁄2 AA 3.67 V 3.6 V 1.1 Ah (1.5 mA) 40 mA – 60/+ 85°C** 14.65 mm 24.8 mm 8.9 g yes Non-restricted
LST 14250 UK
1
⁄2 AA 3.67 V 3.6 V 1.1 Ah (1.5 mA) 40 mA – 60/+ 85°C** 14.4 mm 25.1 mm 9.4 g yes Non-restricted
LS 14250C F
1
⁄2 AA 3.67 V 3.6 V 1.2 Ah (1.5 mA) 15 mA – 60/+ 55°C** 14.65 mm 24.8 mm 8.9 g yes Non-restricted
LS 14500 F AA 3.67 V 3.6 V 2.25 Ah (2 mA) 100 mA – 60/+ 85°C** 14.65 mm 50.3 mm 16.2 g yes Non-restricted
LST 14500 UK AA 3.67 V 3.6 V 2.25 Ah (2 mA) 100 mA – 60/+ 85°C** 14.4 mm 49.8 mm 17.4 g yes Non-restricted
LS 14500C F AA 3.67 V 3.6 V 2.7 Ah (2 mA) 25 mA – 60/+ 55°C** 14.65 mm 50.3 mm 16.2 g yes Non-restricted
LSX 14500 F AA 3.67 V 3.6 V 1.9 Ah (2 mA) 200 mA – 60/+ 85°C** 14.65 mm 50.3 mm 17.5 g pending Non-restricted
LST 17330 UK
2
⁄3 A 3.67 V 3.6 V 2.1 Ah (3 mA) 25 mA – 60/+ 85°C** 16.5 mm 33.4 mm 14.4 g yes Non-restricted
LS 17500 F A 3.67 V 3.6 V 3.4 Ah (4 mA) 150 mA – 60/+ 85°C** 17.0 mm 50.9 mm 21.9 g yes Non-restricted
LSH 26180
F
1
⁄3 C 3.67 V 3.6 V 1.2 Ah (10 mA) 400 mA – 60/+ 85°C** 26.2 mm 18.6 mm 24 g --- Non-restricted
LSH 14 F C 3.67 V 3.6 V 5.5 Ah (15 mA) 1300 mA – 60/+ 85°C** 26.0 mm 50.4 mm 51 g yes Class 9
LSH 14
F C 3.67 V 3.6 V 3.6 Ah (15 mA) 1300 mA – 60/+ 85°C 26.0 mm 50.4 mm 51 g --- Non-restricted
LSH 20 F D 3.67 V 3.6 V 13.0 Ah (15 mA) 1800 mA – 60/+ 85°C** 33.4 mm 61.6 mm 100 g yes Class 9
LS 26500
F C 3.67 V 3.6 V 7.7 Ah (4 mA) 150 mA – 60/+ 85°C** 26.0 mm 49.1 to 50.4 mm*** 48 g yes Class 9
LS 33600 F D 3.67 V 3.6 V 17.0 Ah (5 mA) 250 mA – 60/+ 85°C** 33.4 mm 60.2 to 61.6 mm*** 90 g yes Class 9
LS 33600C F D 3.67 V 3.6 V 18.5 Ah (1 mA) 80 mA – 60/+ 55°C** 33.4 mm 60.2 to 61.6 mm*** 90 g yes Class 9
Production Size Open Nominal Nominal capacity* Maximum Operating Outside Height Weight UL Transport
site circuit voltage (drain) recommended temperature diameter max. recognition status
voltage continuous range max.
current
Small LS/LST/LSX cells
Large LS cells
LSH spiral cells
* 2 V cut-off ** Cells leakproof up to +110°C All LSH cells are fitted with individual 5 Amp fuse protection
“light”
* 2 V cut-off ** Cells leakproof up to +120°C
* 2 V cut-off ** Cells leakproof up to +110°C *** Depending on cell finish
June 2004
Li-SOCl
2
cells
Primary cells and batteries are not rechargeable.