A SERVICE OF

logo

SELF PURGING YOUR 25176B
PROCEDURE FOR PURGING REMAINING REFRIGERANT FROM THE 25176B
1. Close the ports of the system being serviced that
are connected to the input port of the 25176B.
2. Close the input port on the 25176B.
3. Turn off the 25176B.
4. Turn the Recover/Purge valve to the Purge posi-
tion.
5. Restart the 25176B.
6. Run until desired vacuum is achieved.
7. Close the ports on the recovery tank and the
25176B.
8. Turn the 25176B off.
9. Return the Recover/Purge valve to the Recover
position.
10.Disconnect and store all hoses.
11.Replace the in-line filter on your 25176B after
every job.
SELF PURGE/ AUTO EVACUATE
To change from Recovery mode to Purge follow the steps below:
1. Close the Input port
2. Turn the unit off (to prevent high pressure shutoff).
3. Switch to Purge position.
4. Restart the unit.
12
100439_RevC.qxd 9/2/05 3:02 PM Page 11