![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/09/009b7a62-7eda-4625-bdf6-070a1ef460e7/009b7a62-7eda-4625-bdf6-070a1ef460e7-bg5.png)
Constant Running Hydraulic Pump - Installation Guide 5
Installation instructions
Parts required
To install this drive you will need:
• Parts supplied:
• CR hydraulic pump
• if required: BSP to NPT adaptors (x3)
• Additional parts:
• suitable hydraulic pipes, hydraulic fluid, T-pieces, pipe
fittings and thread-sealing compound (see page 8)
• suitable securing bolts, lock washers/lock nuts (see page 7)
• suitable cable and electrical connectors for the drive motor
and solenoid control valves (see page 13)
• CR interface (to connect to Type 100/300 course computer)
• bypass valve (if connecting to a secondary steering ram)
Note: Obtain these additional parts before you start installation.
Installation steps
WARNING: Electrical safety
Make sure you have switched off the power supply before you
start installing this product.
Follow these steps to install your CR pump:
Ï
Ï
Ï
Ï
1
Consult the EMC installation guidelines. page 6
2
Mount the pump. page 7
3
Connect to the hydraulic steering system. page 8
4
Connect to the course computer. page 13
5
Complete the post-installation checks. page 16