For Model 786NS,986NS Series
WARNING :
This product included critical components which are essential for X-Radiation safety.
See service manual for proper replacement.Maximum 2nd anode voltage must not exceed
30KV at any operating conditions.
To measure 2nd voltage use high impedance meter connect (-) chassis, use a high voltage
lead from (+) to 2nd anode.
For Model 572NS Series
WARNING :
This product included critical components which are essential for X-Radiation safety.
See service manual for proper replacement.Maximum 2nd anode voltage must not exceed
27KV at any operating conditions.
To measure 2nd voltage use high impedance meter connect (-) chassis, use a high voltage
lead from (+) to 2nd anode.
VR501,VR601 has been sealed against improper replacement or defeating the control.
Instructions for proper replacement of such sealed controls should also be provided in the
service information.
4