10-5. TROUBLE CRITERION OF MAIN PARTS
MSZ-FD25VA MSZ-FD25VAS MSZ-FD35VA MSZ-FD35VAS
Part name FigureCheck method and criterion
Measure the resistance with a tester.
Refer to 10-7. "Test point diagram and voltage", "Indoor electronic control
P.C. board", the chart of thermistor.
Room temperature
thermistor(RT11)
Indoor coil thermistor
(RT12, RT13)
Horizontal vane
motor(MV1)
Normal
BRN-other one
Measure the resistance between the terminals with a tester.
(Part temperature 10 ~ 30 °C)
336 " ~ 364 "
Color of the lead wire
Vertical vane
motor(MV2)
i-see Sensor
motor(MT)
Normal
Measure the resistance between the terminals with a tester.
(Part temperature 10 ~ 30 °C)
i-see Sensor(RR)
Cover the i-see Sensor with black vinyl tape. Then, turn ON the power
supply. (i-see Sensor is energized.) Measure the voltage between
connector terminals of i-see Sensor with a tester.
(Part temperature 10 ~ 40 °C)
282 " ~ 306 "
Normal range
2(GND)
-
4(+)
1(+)
-
2(GND)
1.874 ~ 3.387 VDC
1.010 ~ 1.420 VDC
i-see Sensor
connector terminals
NOTE: Pay attention to static electricity.
Indoor fan motor(MF)
Check 10-6. A.
PLASMA electrode unit
Check 10-6. F
Color of the lead wire
BRN-other one
RED
YLW
BRN
ORN
GRN
ROTOR
RED
YLW
BRN
ORN
GRN
ROTOR
Cover the i-see
Sensor with
black vinyl tape.
i-see Sensor
i-see Sensor P.C. board
Black vinyl tape
connector
w
4
3
2(GND)
1
OBH488-1.qxp 07.8.9 11:47 AM Page 27