![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/ed/2ed5ee29-4c1e-4497-b8bf-024f6d9c5138/2ed5ee29-4c1e-4497-b8bf-024f6d9c5138-bg8.png)
shut down in a latch off mode while the respective output current exceeds the limit as shown in Table 8.
When the latch has been cleared by toggling the PSON# single or cycling the AC input power. The power
supply module should not be damaged in this condition.
Voltage Minimum Maximum Shutdown Mode
+5Vsb 110% 160% Latch Off
+12V 110% 160% Latch Off
Table 8 –Over Current protection
4.4 Short Circuit Protection
The power supply shall shut down in a latch off mode when the output voltage is short circuit.
5. Environmental Requirements
5.1 Temperature
Operating Temperature Range: 0°C ~ 40°C (32°F~ 113°F)
Non-Operating Temperature Range: -40°C ~ 70°C (-40°F~ 158°F)
5.2 Humidity
Operating Humidity Range: 20% ~ 90%RH non-condensing
Non-Operating Humidity Range: 5% ~ 95%RH non-condensing
6. Agency Requirements
6.1 Safety Certification.
Product Safety: UL 60950-1 2000Edition, IEC60950-1, 3
rd
Edition
EU Low Voltage Directive (73/23/EEC) (CB)
TÜV
RFI Emission: FCC Part15 ( Radiated & Conducted Emissions )
CISPR 22,3
rd
Edition / EN55022: 1998 + A1: 2000)
PFC Harmonic:
EN61000-3-2:2000
Flicker:
EN61000-3-3: 1995 + A1: 2002
Immunity against:
-Electrostatic discharge:
-Radiated field strength:
-Fast transients:
-Surge voltage:
EN55024: 1998 + A1: 2001 and A2: 2003
-IEC 61000-4-2
-IEC 61000-4-3
-IEC 61000-4-4
-IEC 61000-4-5