A SERVICE OF

logo

T~
PROBLEM
SOL~R
(continued)
PROBLEM POSSIBLE CAUSE
WATER LEAKS
Make sure hose connections are tight at faucets.
Make sure end of drain hose is correctly inserted in and secured to drain facility.
WASHER IS NOISY
Make sure washer is level and
flrrn
to the floor with robber foot pads in place and
front jam nuts tight. See your Installation Instructions.
A sharp, distinctive sound will be heard at the end of each spin period as the motor
stops and the spin brake inside the transmission “locks in.” This sound is normal.
Heavily unbalanced loads can cause the washer to vibrate excessively during spin, and
may cause it to move from its original position. In extreme cases (usually occurs when
washing a single, heavy item or a small load when water level is set higher than
necessary), the spin basket may strike the outer tub, creating a loud but harmless noise.
To correct, open the lid and redistribute the load evenly about the wash basket. Close
the lid and restart.
WASHER PAUSES
Washer normally pauses between washing steps.. such as between wash and spin or
IN CYCLE between spin and rinse.
If you need more
help...call,
toll free: GE Answer Center
@
/ 800.626.2000/consumer information service
CARE
Am
CLEANING
USER MAINTENANCE INSTRUCTIONS
The Tub.
The porcelain is self-cleaning. Leave lid
To Store Washer.
Ask service technician to remove
open after washing to allow moisture to evaporate.
water from drain pump and hoses to prevent freezing.
Do not use harsh or gritty cleansers.
Do not store the washer where it will be exposed
The Exterior.
Wipe off any spills of washing
to the weather.
compounds. Wipe or dust with damp cloth. Try
For Long Vacations.
Be sure water supply is shut off
not to hit surface with sharp objects.
at faucets and drain all water from hoses if weather
will be below freezing.
How to remove the agitator
To remove limestone from
Filter-Flo
pan
To remove the agitator,
snap the cap off and remove
the screw. Then remove
the agitator extender (on
models so equipped)
and the agitator.
To replace the agitator,
carefully lower it straight
down onto the shaft so
that it fits snugly into
place.
Replace the agitator
extender (on models so
equipped), the screw
and the cap.
22
Cap
Soak filter pan in a preheated
160°F.
(71 ‘C.)
i
Screw
solution of half vinegar and half water for 15
;,
Agitator
minutes. Then brush each side of pan with a stiff
Extender
bristle brush while flushing with running water.
A
(on some models)
,,
— Agitator
~j
CAUTIONS:
)
Do not soak in porcelain container. Vinegar
.,.
can damage porcelain.
A
Do not exceed
180°F.
(82°C.
) or filter pan
Shaft
may warp.
(Appearance may