4-wire receptacle
(NEMA type 14-30R)
Electrical connection (non-Canada) - 4 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block access 2.
cover in the lower corner on the back of the dryer.
Install a UL-approved strain relief according to the power 3.
cord/strain relief manufacturer’s instructions in the power
cord entry hole below the access panel. At this time, the
strain relief should be loosely in place.
Thread an UNPLUGGED, UL-approved, 30 amp. power 4.
cord, NEMA 14-30 type ST or SRDT, through the strain
relief.
Disconnect the internal (BLACK) dryer harness ground 5.
wire from the (GREEN) ground screw next to the terminal
block.
Attach the ground (GREEN) power cord wire to the 6.
cabinet with the ground (GREEN) screw. Tighten the
screw securely.
Move the internal dryer harness ground (BLACK) wire to 7.
the terminal block and attach it along with the neutral
(WHITE) power cord wire conductor to the center, SILVER
colored terminal on the terminal block. Tighten the screw
securely.
Attach the RED and BLACK power cord conductors to 8.
the outer, BRASS colored terminals on the terminal block.
Tighten both screws securely.
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Terminal
block
Neutral
(WHITE wire)
30 AMP
NEMA 14-30
Ground
(GREEN wire)
Follow manufacturer’s guidelines for fi rmly securing the 9.
strain relief and power cord.
Reinstall the terminal block cover.10.
Move internal ground (BLACK)
Move internal ground (BLACK)
wire to neutral (SILVER)
terminal for 4-wire system.
terminal for 4-wire system.
Neutral
terminal
GREEN
ground screw
BLACK or
RED power wire
BLACK
or RED
power wire
GREEN
ground wire
WHITE
neutral wire
12
- ELECTRICAL SHOCK HAZARD - Failure
to disconnect power source before servicing could result in
personal injury or even death.
- ELECTRICAL SHOCK HAZARD - Do not
make a sharp bend or crimp wiring/conductor at connections.
If a terminal screw falls during cord installation, it
can be retrieved in the terminal screw recovery slot below the
access panel.