![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/57/25724735-77b8-44bd-b2c2-4d9608e50392/25724735-77b8-44bd-b2c2-4d9608e50392-bgc.png)
10
B
CAUTION:
36" min. to
combustible
material ,
from cooking
surface
A
C
D
E
F
G
H
K
I
J
electrical
and
gas supply
As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest
edition).
The horizontal surfaces of the range top (cooktop) trim must not be
below countertop level.
NOTE: See manufacturer's recommendations for ducting
specifications.
NOTE: When installing a 30" Cooktop with a Downdraft (DD-30SS), a
minimum of a 26" cabinetry depth is required.
WHEN INSTALLING WITH A DCS DD-36 OR DD30 DOWNDRAFT VENTILATION SYSTEM
A 18” MIN.
B 13” MAX.
C 55/8” MIN. TO COMBUSTIBLES FOR CDU365
511/16” MIN. TO COMBUSTIBLES FOR CDU304
D 193/4” DEPTH
E 343/4” WIDTH FOR CDU365
285/8” WIDTH FOR CDU304
F 331/2” WIDTH FOR DD36
271/2” WIDTH FOR DD30
G 1/2” MIN.
H 25/8”
I 9”
J 261/2”
K MIN. 36” FOR CDU365
MIN. 30” FOR CDU304
INSTALLATION INSTRUCTIONS
A 18” MIN.
B 13” MAX.
C 55/8” MIN. TO COMBUSTIBLES FOR CDU365
511/16” MIN. TO COMBUSTIBLES FOR CDU304
D 193/4” DEPTH
E 343/4” FOR CDU365
285/8” FOR CDU304
F 36” HOOD WIDTH MIN. FOR CDU365
30” HOOD WIDTH MIN. FOR CDU304
G 21/2”
H 5”
I 18”
WHEN INSTALLING WITH A RANGEHOOD
CUTOUT AND CABINETRY DIMENSIONS
F
CAUTION:
36" min. to
combustible
material ,
from cooking
surface
B
A
C
D
E
As defined in the “National Fuel Gas Code” (ANSI Z223.1, latest edition).
NOTE: See manufacturer's recommendations for ducting specifications.
G
H
electrical
and
gas supply
I
US