A SERVICE OF

logo

TP T 15HD 45 and TP T A 45 • Installation
Installation
2-4
N
Strip approximately 0.43 inch (1.1 cm) of insulation
from each individual wire on one end of a TP cable.
1
1&2
3&6 4&5
7&8
2345678
Twisted Wire Pairs
c
Power input captive screw connector — Connect power
input cables to the 2-pole female direct insertion captive screw
connector.
12 VDC
.5A MAX.
Power Input Captive Screw
Direct Insertion Connector
-
+
W
Remove power before wiring.
d
Digital audio output captive screw connector — Connect the
digital audio output cables to the 2-pole female direct insertion
captive screw connector.
Digital Audio Output
Captive Screw Direct Insertion Connector
AUDIO
AUDIO
-
+
W
Remove power before wiring.