5 PERIPHERAL CIRCUITS AND THEIR OPERATION (I/O Memory Map)
Table 5.1.1(d) I/O Memory map (00FF19H–00FF22H)
SR R/WAddress Bit Name Function Comment10
00FF19 D7
D6
D5
D4
D3
D2
D1
D0
PRPRT7
PST72
PST71
PST70
PRPRT6
PST62
PST61
PST60
Programmable timer 7 clock control
Programmable timer 7 division ratio
Programmable timer 6 clock control
Programmable timer 6 division ratio
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
On
On
Off
Off
PST72
1
1
1
1
0
0
0
0
PST71
1
1
0
0
1
1
0
0
PST70
1
0
1
0
1
0
1
0
(OSC3)
f
OSC3
/ 4096
f
OSC3
/ 1024
f
OSC3
/ 256
f
OSC3
/ 64
f
OSC3
/ 32
f
OSC3
/ 8
f
OSC3
/ 2
f
OSC3
/ 1
(OSC1)
f
OSC1
/ 128
f
OSC1
/ 64
f
OSC1
/ 32
f
OSC1
/ 16
f
OSC1
/ 8
f
OSC1
/ 4
f
OSC1
/ 2
f
OSC1
/ 1
PST62
1
1
1
1
0
0
0
0
PST61
1
1
0
0
1
1
0
0
PST60
1
0
1
0
1
0
1
0
(OSC3)
f
OSC3
/ 4096
f
OSC3
/ 1024
f
OSC3
/ 256
f
OSC3
/ 64
f
OSC3
/ 32
f
OSC3
/ 8
f
OSC3
/ 2
f
OSC3
/ 1
(OSC1)
f
OSC1
/ 128
f
OSC1
/ 64
f
OSC1
/ 32
f
OSC1
/ 16
f
OSC1
/ 8
f
OSC1
/ 4
f
OSC1
/ 2
f
OSC1
/ 1
00FF1B D7
D6
D5
D4
D3
D2
D1
D0
PRTF7
PRTF6
PRTF5
PRTF4
Programmable timer 7 source clock selection
Programmable timer 6 source clock selection
Programmable timer 5 source clock selection
Programmable timer 4 source clock selection
Constantly "0" when
being read
0
0
0
0
R/W
R/W
R/W
R/W
f
OSC1
f
OSC1
f
OSC1
f
OSC1
f
OSC3
f
OSC3
f
OSC3
f
OSC3
00FF20 D7
D6
D5
D4
D3
D2
D1
D0
PK01
PK00
PSIF1
PSIF0
PTM1
PTM0
Constantly "0" when
being read
0
0
0
R/W
R/W
R/W
K00–K07 interrupt priority register
Serial interface interrupt priority register
Clock timer interrupt priority register
00FF21 D7
D6
D5
D4
D3
D2
D1
D0
PPT3
PPT2
PPT1
PPT0
Constantly "0" when
being read
Constantly "0" when
being read
PPT3
PPT1
1
1
0
0
PPT2
PPT0
1
0
1
0
Programmable timer 3–2 interrupt
priority register
Programmable timer 1–0 interrupt
priority register
Priority
level
PK01
PSIF1
1
1
0
0
Priority
level
PK00
PSIF0
1
0
1
0
Level 3
Level 2
Level 1
Level 0
Level 3
Level 2
Level 1
Level 0
00FF22 D7
D6
D5
D4
D3
D2
D1
D0
ETM32
ETM8
ETM2
ETM1
Clock timer 32 Hz interrupt enable register
Clock timer 8 Hz interrupt enable register
Clock timer 2 Hz interrupt enable register
Clock timer 1 Hz interrupt enable register
0 R/W
Interrupt
enable
Interrupt
disable
0
0
R/W
R/W
Constantly "0" when
being read
PTM1
1
1
0
0
Priority level
PTM0
1
0
1
0
Level 3
Level 2
Level 1
Level 0