1.2.2 Electrical Specifications
Table 1-5. Electrical Requirements and Ranges
Description 100 V Version 200 V Version
Rated voltage 100 ∼ 120 VAC 220 ∼ 240 VAC
Input voltage range
90 ∼ 132 VAC 198 ∼ 264 VAC
Rated frequency range
50 ∼ 60 Hz
Input frequency range
47 ∼ 63 Hz
Power consumption Less than 500 W Less than 600 W
Power consumption while in
standby mode
Less than 15 W
(without option)
1.2.3 Reliability Specifications
MPBF (Mean Prints Between Failures): Over 25,000 sheets
Note:
MPBF indicates average number of pages printed before occurrence of problem requiring
replacement or service.
MTBF (Mean Time Between Failures): 3000 power on hours (POH)
Jam rate: 1 out of 2,000 sheets or less (excluding multiple-sheet feeding)
Feed failure: 1 out of 2,000 sheets or less (excluding multiple-sheet feeding)
Multiple paper feeds: 1 out of 500 sheets or less
Paper curl height: 30 mm (1.2 inches) or less
Leading edge bending (1 cm or more): 1 out of 1,000 sheets
MTTR (Mean Time To Repair): 30 minutes or less
Durability: 5 years or 180,000 sheets
1.2.4 Environmental Conditions for Operation (Including Imaging Cartridge)
Temperature:
10 to 35° C (50 to 95° F)
Humidity: 15 to 85% RH
Altitude: 2,500 m (8,200 feet) or lower
Levelness:
1°
Illuminance: 3,000 lux or less (Must not be exposed to direct sunlight.)
Surrounding space: Printer should have at least 100 mm of clearance on its
sides and rear.
1.2.5 Environmental Conditions for Storage and Transportation
Temperature:
0 to 35° C (32 to 95° F)
Humidity: 30 to 85% RH
Drop test: Clear to JIS Z0200-1987 Level 1
Vibration: Vibration frequency 5 to 100 Hz and 100 to 5 Hz
Acceleration 1 G
Acceleration direction 3 direction
Resistance to atmospheric pressure: More than 61.3 KPa
Storage life: 18 months (following date of manufacture)
General Description EPL-5500 Service Manual
1-6 Rev. B