PowerConnect B-Series FCX Configuration Guide 1411
53-1002266-01
Syslog messages
41
Notification OSPF virtual intf config error,
rid <router-id>, intf addr <ip-addr>,
pkt src addr <src-ip-addr>,
error type <error-type>, pkt type <pkt-type>
Indicates that an OSPF virtual routing
interface configuration error has occurred.
The <router-id> is the router ID of the Dell
PowerConnect device.
The <ip-addr> is the IP address of the
interface on the Dell PowerConnect device.
The <src-ip-addr> is the IP address of the
interface from which the Dell PowerConnect
device received the error packet.
The <error-type> can be one of the
following:
• bad version
• area mismatch
• unknown NBMA neighbor
• unknown virtual neighbor
• authentication type mismatch
• authentication failure
• network mask mismatch
• hello interval mismatch
• dead interval mismatch
• option mismatch
• unknown
The <packet-type> can be one of the
following:
• hello
• database description
• link state request
• link state update
• link state ack
• unknown
Notification OSPF virtual intf rcvd bad pkt,
rid <router-id>, intf addr <ip-addr>,
pkt src addr <src-ip-addr>,
pkt type <pkt-type>
Indicates that an OSPF interface received a
bad packet.
The <router-id> is the router ID of the Dell
PowerConnect device.
The <ip-addr> is the IP address of the
interface on the Dell PowerConnect device.
The <src-ip-addr> is the IP address of the
interface from which the Dell PowerConnect
device received the authentication failure.
The <packet-type> can be one of the
following:
• hello
• database description
• link state request
• link state update
• link state ack
• unknown
TABLE 239 Syslog messages (Continued)
Message level Message Explanation