AS-1412 Installation Guide P. 13
Caution: The relay output rating on this Unit is 25 A at most. Defective OEM solenoid
switches can sometimes draw up to 50 or 60 A, causing the 30 A fuse to blow. Always
check your circuit with a proper measuring device.
Ignition-controlled Door Locks
(
OFF – by default.) This feature will automatically lock all Doors as soon as the Key is
turned to the
IGNITION ON (RUN) position and the Brake Pedal is pressed. When the Ignition
Key is turned to the
OFF position, the Doors will automatically unlock.
Secure Lock
(
OFF by default.) This feature allows the Module to control certain OEM factory Alarm
systems that use the factory Lock wire to arm the Alarm and the Unlock wire to disarm it.
If Secure Lock is disabled (Option 1), the Module will still disarm before remote-starting the
vehicle. If Secure Lock is enabled (Option 2), upon receiving a remote
START signal the
Module will
UNLOCK the Doors (disarming the factory Alarm); 1/2 sec. after remote start it will
re-lock the Doors. 4 seconds after shutdown, Secure Lock will re-lock all Doors once more
(arming the system again). Please note that most OEM systems will not rearm the Alarm
while the Engine is running, but will lock the Doors.
Passive or Active Arming Starter Kill
(Passive with a 1-min. timeout – by default.) The Starter Kill can be programmed to be
active (will not arm automatically) or passive (will arm automatically). In Passive Mode,
you can program it to arm automatically after 1 or 3 min.
To disarm the Starter Kill in Active or Passive Mode, the user must press and hold button
,
(or enable Valet Mode). The Parking Lights will flash twice. If the Door Locks option was
installed, this will also unlock the Doors.
To arm the Starter Kill in Active or Passive Mode, the user must press and hold button
,.
The Parking Lights will flash once. (If the Door Locks option was installed, this will also lock
the Doors). In Passive Mode, the system will automatically arm itself 1 or 3 minutes after the
Engine is shut down.
Lock Pulse Duration
(7/10
th
sec. LOCK and UNLOCK – by default.) The Door Lock pulse duration can be
programmed to give 7/10-sec.
LOCK and UNLOCK pulses (by default), 4-sec. LOCK and
UNLOCK pulses, or for a 7/10-sec. LOCK pulse and two 1/4 -second UNLOCK pulses (used for
double-pulse disarm/unlock systems).
Engine Run Time
(4 / 15 / 25 min. – by default.) In GAS mode the Module can be programmed to keep the
Engine running for 4, 15 (default), or 25 minutes. In
DIESEL mode the Module can be set to 9,
20 (default) or 30 min.
Idle Mode
(
ON – by default.) When programmed, this option allows the user to engage the remote
starter to take over the vehicle while it is already running. This option will keep the vehicle
running for the pre-programmed run time, or until it is shut down.
Resetting the Module (without the plug-in valet)
Resetting the Module is not a required process. Most of the time, you can avoid resetting the
Module by fixing the issue directly at the root of the cause.
To reset the Module, without using the plug-in Valet button: