A SERVICE OF

logo

6
12. The pump is now
ready for use
All pump models using the supplied 34” (865mm) suction tube
should prime within 10 seconds after pump is turned on.
Pumps installed at a height upto 5’ (1.52 m) may have diculty
in priming. Follow the procedure below to initiate priming. Pumps
installed at a suction height above 5’ (1.52m) may have diculty
in holding prime. It is recommended that a foot valve with ball
check (not supplied with the pump) be added to the bottom of the
suction tube to maintain prime
PRIMING
1. Remove the Elbow from the pump outlet
2. Pour fuel being pumped into the pump outlet until completely
lled
3. Re-assemble the Elbow back into the pump outlet & turn the
pump on. Pump should get primed in less than 10 seconds
4. If pump still does not gain prime, check for any major leaks
in the system. If no leaks are found , then the pump is
mechanically defective & should be reported back to your
Distributor
4. In less than 10 seconds, the pump will be primed & fuel will
start dispensing from the Nozzle
5. Dispensing Action can be stopped by closing the Nozzle, with
the pump still ON. This however must not be done for more
than 5 minutes. DO NOT operate the pump for more than 30
minutes continuously in 1 hour
6. It is best practice to Switch Lever in the OFF position to stop
dispensing
7. The pump must never be run dry (no media in the drum) as
that can possibly cause irreparable damage to the motor
8. Once Dispensing is completed, switch o the Lever &
disconnect power supply to the pump
9. Store the Nozzle Back into the Nozzle Holder
WARNING
Do not use curb pump auto nozzle with this pump. Contact your
distributor for auto nozzles for use with electric fuel pumps
PUMP OPERATION
1. Remove Nozzle
from the Nozzle
Holder. The On\
O switch can be
Switched ON only
once the nozzle is
removed from the
nozzle holder
2. Nozzle should be facing the container into which Fuel is to be
dispensed
Pump in ON Position
ON
OFF
3. Pump On/O
Switch Lever is
located under the
nozzle holder. Move
switch lever ON &
simultaneously open
the Nozzle
1. Clean Inlet Strainer after every 50 hours of operation
2. Inlet strainer is easily accessible without having to dis-
assemble the pump. Strainer is installed just above the pump
inlet & can be accessed by removing the 4 bolts on the side of
the pump holding the Strainer cover
3. Remove & clean strainer
4. If strainer is excessively dirty, clean tank to protect pump and
the equipment being fuelled
5. After cleaning strainer, replace strainer & cover. Make sure
cover seal is in place
MAINTENANCE
Strainer