4-19
3. The length of the spring (installed)
changes 1.5 mm (0.06 in) per turn of the
adjusting nut.
A. Spring length
4. Tighten the locknut to the specified
torque.
CAUTION:
_
Always tighten the locknut against the ad-
justing nut and tighten it to the specified
torque.
_
Measurement
A
:
Installed length:
Minimum (hard): 232 mm (9.1 in)
Standard: 240 mm (9.4 in)
Maximum (soft): 247 mm (9.7 in)
Tightening torque:
42 Nm (4.2 m·kgf, 30 ft·lbf)
U5LP12.book Page 19 Friday, April 26, 2002 2:47 PM