United States Stove 5500M Remote Starter User Manual


 
18 USSC
Error
Code
Err1
Err2
Err3
Err4
Err5
Err6
Err7
Err8
Error
Descrption
Thehighlimittemperaturesensor
hastripped.
Stoveranoutoffuelduringnormal
operation.
The stove was unable to reach the
RoomFanOntemperaturewithinthe
startuptime.
Thepowerfailedwhilethestovewas
hot, and when power was restored,
therewasout.
TheAugeroutputfusehasblown.
TheIgnitoroutputfusehasblown.
The Draft Fan (Exhaust Fan) output
fusehasblown.
TheRoomFanoutputfusehasblown.
Possible
Causes
• Inadequateventilation.
• Roomfanfailure.
• ExhaustBlockage.
• ElectricalOpenintheovertemperatureswitchorwiring.
• HopperEmpty.
• Augeroutputfailureorjam.
• Flameoffuelqualitycausedretoburntooslowlyorgoout.
• ElectricalOpeninlowtemperatureswitchorwiring.
• FlameorFuelqualitycausedtheretoburntooslowlyorgo
out.
• AugeroutputfailureorjamHopperemptyonstartup.
• ElectricalOpeninlowtemperatureswitchorwiring.
• Powerloss
• Augermotorjammedorbad.
• Ignitorshortedoutorbad.
• DraftFanmotorjammedorbad.
• Roomfanmotorjammedorbad.

Severalsituationsoreventsareindicatedinnormaloperationbyblinkingdisplayindicatorsorsegmentsinthedisplay:
Thismeansthatthestoveisinthe“StartUp”statewaitingforeithera3minutetimeouttobegin
burningorforthestovetoreachthewarmtemperaturewhichevercomesrst.
Thisindicatesthatthestoveisinthe“Shutdown”statewaitingfortheOFFbutton,orfora15
minuteperiodafterthestovewasturnedoff,orforthestovetocooldown,orforthedoortobeclosed.
Thisindicatesthatthestoveisinthenormalrunmodeandisrampingfrom
thecurrentheatrangesettingtothetargetheatrangesetting.Oncetherampiscomplete,thedashwillstopashing.
Forrampingfromheatrange1to5,thedefaulttimeis12minutes(witha90secondramptime).
Thisindicatesthatthestoveisinnormaloperationandisrunningintheautomatic
mode.However,eithertheDraftFanorAuxiliarysettingismanuallycongured.
Thisindicatesthatthestoveisinnormaloperationandthatthevacuumsensor
detectsalossofpressureeitherbecausethedoorisopenorbecausethereisanegativepressureintheroomwith
respecttotheexhaust.
Thisindicatesthattheignitorisonduringthelightingstage.
Thisindicatesthatthestoveisin
normaloperationandthatanovertemperatureconditionexistscausingthefueltostop.
Thisindicatesthatthestoveisinacut
backconditioninanattempttopreventanovertemperatureshutdown.

Toreturnthecontroltoitsoriginalfactorydefaultsettings,pressandholdtheAUXUPandAUXDOWNbuttonstogether
forthreeseconds.
Error Codes and Display Indicators