CATEGORY RATINGS DEFINITIONS
IEC 1010
Over Voltage:
Cat II - 1000V
CAT III - 600V
Pollution Degree 2
CAT II - 1000V Installation Category (Overvoltage
Category) II: Includes voltages encountered on the step
down side of the transformer on the building and at a
distance of 10 meters from the CAT III source.
CAT III - 600V Installation Category (Overvoltage
Category III: Includes voltage encountered on the distri-
bution level with short distance to the main service con-
nection.
Pollution Degree 2 Normally only nonconductive pol-
lution occurs. Occasionally temporary conductivity
caused by condensation must be expected.
SAFETY CONSIDERATIONS
WARNING: Please follow manufacturers test
procedures whenever possible. Do not attempt
to measure unknown voltages or components
until a complete understanding of the circuit is
obtained.
GENERAL GUIDELINES
ALWAYS
Test the 100 before using it to make sure it is
operating properly.
Inspect the test leads before using to make sure
there are no breaks or shorts.
Double check all connections before testing.
Have someone check on you periodically if
working alone.
Have a complete understanding of the circuit
being measured.
Disconnect power to circuit, then connect test leads
to the 100, then to circuit being measured.
NEVER
Attempt to measure unknown high voltages.
Connect the test leads to a live circuit before
setting up the instrument.
Touch any exposed metal part of the test lead
assembly.