MAXFORCE BREAKER User Manual ◄ 27
CHARGING THE SIDE ACCUMULATOR
Thetoolsrequiredtochargethebreakerareshownbe-
low.The33464adapterand 33300adapterassembly
canbeobtainedindividuallyorinakit(P/N33465).Note
thattheadapterandadapterassemblyaredesignedto
be used with the 505232 charge hose assembly and
the 28257 accumulator tester which are used with other
Stanley model breakers. When charging the breaker,
makesurethetoolsandchargevalveareclean.Dirtcan
contaminatethechargevalveandcauseleakage.
1. Remove theprotective plugfrom theaccumulator
cover.
2. Screwtheadapterassembly(P/N33464)ontothe
tester(P/N28257)andtightenit.
3. Holdthechuckendofthetesterandturnthegauge
fullyclockwiseuntilthegaugestopsturning.Donot
tighten.
4. Screwthetesterintothethreadedhole,inplaceof
theremovedprotectiveplug,byturningthechuck.
Donotusethegaugeforturning.Tightenthechuck
lightly to ensure a good seal.
5. Removethecapandthenturnthechargevalve1
to2turnscounterclockwiseuntilapressureisindi-
cated on the gauge.
Figure 23. Charging the Side Accumulator
6. If the pressure is correct, turn the charge valve
clockwiseuntilitstopsandthentightenslightly.Un-
screwthetesterandreinstalltheplugandcap.Ifthe
pressureisnotcorrect,proceedtoStep7.
7. Connect the charge hoseassembly to the charg-
ingvalveonthetester.Makesurethevalveonthe
chargehoseassemblyisclosed.Openthevalveon
thenitrogenbottle.
8. Veryslowlyopenthevalveonthechargehoseas-
semblyandslowlymeterthenitrogenintothebreak-
er charge valve until the tester reads the correct
chargepressure.
9. When the correct pressure is obtained, close the
valveonthechargehoseassemblyandontheni-
trogenbottle.Turnthechargevalveclockwiseuntilit
stopsandthentightenslightly.Unscrewandremove
the charge hose assembly. Unscrew and remove
thetester.ApplyLoctite™242andreinstalltheplug
andcap.
Nitrogen Bottle
(locallyobtained)
505232 Charge Hose Assy
(Includesgauge,valve,hose
andchargevalveadapter)
28257Tester
33464Adapter
ChargeValvePlug
CHARGE PRESSURE FOR THE
SIDE ACCUMULATOR
60 bar ± .5
870 psi ± 8
ChargeValve
Cap
IMPORTANT
SeeSpecicationspageforcorrect
chargepressure