Scytek electronic 5100RS Automobile Alarm User Manual


 
Galaxy 5100RS - Page 33Page 33 -Galaxy 5100RS
10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a
residual dome light circuit that remains on for a period of time after closing the door.
11. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system
is armed. This feature can be used to roll-up windows, close sunroofs, activate accessories, etc.
(will not activate if Aux 2 is programmed for “latch”
12. Auxiliary 2 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 2.
Momentary
operation provides an output for as long as the transmitter button is pressed.(1-way
remote only).
Timed
operation provides an output that turns on for 10 seconds each time the transmitter button is
pressed. If the button is pressed again during the 30 seconds, the output will turn off.
Latched
operation provides an output that turns on when the transmitter button is pressed and remains
on until the transmitter button is pressed again.
Note: With the optional ScyNet network interface and Wizard software, any auxiliary function can be
programmed to output for 1 second up to 255 seconds.
13. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to open the
trunk) will disarm the alarm the system.
14. Auxiliary 3 Output Mode. Selects between Channel 3 or Factory Rearm output.
15. Start in Valet Mode. Selects whether or not the vehicle can remote start while in the valet mode.
16. Lock After Start. When selected, the doors will automatically lock after remote starting.
17. Lock After Shutdown. When selected, the doors will automatically lock after remote shutdown.
18. Engine Run Time. Selects between 15 or 25 minutes for the remote start run cycle.
19. Automatic Start Mode. Selects between every two hours or every four hours for the automatic
engine starting feature.
20. Tachless Sense Crank Time. Selecting engine crank time automatically selects the tachless mode
and one of three crank times.
If the normal engine crank time is too short increase the time by selecting one of the two additional
extended crank time options.
Normal - 0.8Sec.
Extended - 1.0Sec.
Super Extended - 1.4Sec.
T
achless Mode. Determines the engine status using an advanced software routine, without requiring
connection to the vehicle’s tachometer. Tachless operation may not be compatible with some vehicles
or in severe temperatures, in which case the tach wire must be connected.
21. RPM Learn/Tach Monitor This dual program branch sets the engine mode for Gas or Diesel, and
learns the vehicle’s RPM threshold. For installation into a diesel equipped vehicle, first set the engine
type to diesel before learning RPM.
RPM Learn/T
ach Monitor. start the engine, enter Branch 21, the LED light will flash continually to
indicate it is reading the tach signal, if not, recheck your tach wire connection. Press Button 1 to learn
the vehicle’s tach signal. The siren*/horn will chirp/honk and the LED will flash once to confirm learning
of the tach signal.