Renaissance Group RB5C4848RR Automobile User Manual


 
13
TECHNICAL DATA
R
888 Porter Rd. Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com
Control Settings—RB5C4848R
Mechanical Settings
Pressure Settings – S/Contained
Differental 60
High Side Cut-In 260
Superheat 8-10
Control Settings
Set Point (Supply Air) SP 22 Maximum Defrost Duration dd 45
Hysteresis HY 9 Dripping Time dC 0
Low Setup Stop LL 20 First Defrost After Power On dU OF
High Setup Stop HL 50 Display During Defrost dP 0
Anti-Short Cycle Delay CC 3 Display Delay After Defrost dr 20
Deep Freezing Time Co 0 60 Digital Input Function iF 0
High Temperature Alarm AH 15 Digital Input Time Delay id 10
Low Temperature Alarm AL -10 Fan Operating Function FF 0
Alarm Differential Ad 5 Fan Startup Delay (After Defrost) Fd 0
Alarm Time Delay At 30 Fan Startup Temperature After Defrost End Fr 40
Defrost Type dF 0 Sensor Failure Operation SF 2
Defrost End Mode dE 1 Temperature Sensor Offset So 0
Defrost Termination Temperature dt 45 Temperature Units Used Un 1
Defrost Interval di 6 Display Refresh Rate PU 1
Electronic Controller
Mechanical
Control Settings—RB5C5948R
Mechanical Settings
Pressure Settings – S/Contained
Differental 60
High Side Cut-In 260
Superheat 8-10
Control Settings
Set Point (Supply Air) SP 22 Maximum Defrost Duration dd 45
Hysteresis HY 8 Dripping Time dC 5
Low Setup Stop LL 20 First Defrost After Power On dU OF
High Setup Stop HL 50 Display During Defrost dP 0
Anti-Short Cycle Delay CC 3 Display Delay After Defrost dr 20
Deep Freezing Time Co 0 60 Digital Input Function iF 0
High Temperature Alarm AH 15 Digital Input Time Delay id 10
Low Temperature Alarm AL -10 Fan Operating Function FF 0
Alarm Differential Ad 5 Fan Startup Delay (After Defrost) Fd 0
Alarm Time Delay At 30 Fan Startup Temperature After Defrost End Fr 40
Defrost Type dF 0 Sensor Failure Operation SF 2
Defrost End Mode dE 1 Temperature Sensor Offset So 0
Defrost Termination Temperature dt 45 Temperature Units Used Un 1
Defrost Interval di 6 Display Refresh Rate PU 1
Electronic Controller
Mechanical