Raypak 504-2004 Automobile User Manual


 
Catalog No.: 6000.29B Effective: 7-15-08 Replaces: 1-1-08
MVB – Type P
Models 504-2004 Model
Shown without H-bypass or Cold Water Run options
Dimensions (in.)
MBTUH
B D E F G H K M N P R V
Model
Input Output Height
NPT NPT Flue Ø
C/A Ø
Ship
Weight
(Lbs.)
Foot-
print
(Ft
2
)
Amps*
P-504 500 420 43 30 35 23-3/4 1 2 8 14-1/8 6 36 8 2 600 5.4 12
P-754 750 630 49 36 41 29-3/4 1 2 10 16 6 42 8 2 660 5.4 12
P-1104 1100 935 55 43 47 35-3/4 1-1/4 2-1/2 10 16 6 49 8 2 720 5.4 12
P-1504 1500 1275 61 50 53 41-3/4 1-1/4 2-1/2 12 18-1/8 8 53 8 2 780 5.4 12
WHP-2004 1900 1615 75 61 65 53-3/4 2 2-1/2 14 20-1/8 8 69 9 5 940 5.4 18
- Ratings shown are for elevations up to 4,500 feet. For installations at elevations
above 4,500 feet, please consult the factory for additional instructions.
* Current draw is for heater only.
(Supply breaker must have delayed trip.)
RATES OF FLOW
20°F
T
Minimum Flow Maximum Flow
Model
GPM
P (ft.)
GPM
P (ft.)
T (°F)
GPM
P (ft.)
T (°F)
P-504 N/A N/A 65 5.5 13 100 11.3 9
P-754 65 6.4 65 6.4 20 100 13.8 13
P-1104 94 13.6 85 11.5 22 113 18.6 17
P-1504 N/A N/A 102 18.7 25 113 22.2 23
WHP-2004 N/A N/A 102 22.7 32 113 27.2 29
Raypak, Inc.
2151 Eastman Avenue, Oxnard, CA 93030
(805) 278-5300
Fax (800) 872-9725
www.raypak.com
CLEARANCES
Certified
Minimum
Recomm.
Service
Front 24” 24”
Rear 12” 24”
Right 1”
Left 1”
Top 0” 10”
Floor 0”
Vent 1”
PUMP
Pump
Model
Model HP Amps*
P-504 1611 ¼ 6
P-754 1630 ½ 7
P-1104 1630 ½ 7
P-1504 1634 1 14
WHP-2004 1636 1 ½ 22
* Current draw is for pump only