Python Model 902 Automobile Alarm User Manual


 
36
© 2006 directed electronics
disarming diagnostics
Extra disarm chirps are the Tamper Alert. If four chirps are heard
when disarming, the system was triggered in your absence. If five
chirps are heard, a zone was triggered so many times that Nuisance
Prevention
®
Circuitry has bypassed that zone (see NPC section of
this guide). The in-vehicle status LED will indicate which zone was
involved. (See Table of Zones section of this guide.) The system will
retain this information in its memory, and continue to chirp four
or five times each time it is disarmed, until the next time the igni-
tion key is turned on.
system status chirps
The siren will chirp when arming/disarming the system. The
pattern of chirps will audibly report the system’s status as
described below.
Action Number of Chirps Description
Arm 1 System armed
Arm 1 (3-second delay), 1 System armed with
Bypass Notification
Disarm 2 System disarmed
Disarm 4 System disarmed with
Tamper Alert
Disarm 5 System disarmed NPC
®
active