37
FEATURES
Instrumentation
MFD Digital Display Programs
Engine Program
Altitude (if equipped)
The rider can calibrate the altimeter for current
atmospheric conditions. Altimeter accuracy
will be +/-300 ft. (91 m) after adjustment.
NOTE: Press and hold the MODE switch for
ten seconds to switch between stan-
dard and metric units of measure-
ment. When "ALt" displays, the program is in the metric mode.
1. Enter the Engine Program and select the altimeter display.
2. Press and hold the SET button for five seconds.
3. When the digits begin to flash, press the SET button once to
advance 50 feet (15 m), or press and hold the button to advance 100
ft. (30 m) every 0.1 seconds. Adjust the altitude display to within 50
ft. (15 m) of current altitude.
NOTE: The gauge reads barometric pressure and allows the rider to
compensate for daily fluctuations in air pressure. The gauge
can adjust the displayed altitude to +/- 1300 ft. (396 m) from the
preset value. It will adjust up to +1300 ft. (396 m) above the
calibrated altitude. Once the +1300 ft. (396 m) offset has been
reached, the next adjustment is -1300 ft. (396 m) from the cali-
brated altitude, and 50 ft. (15 m) will be added to the altitude
each time the SET button is pressed.
4. Press the MODE button to hold the reading at the adjusted value. If
it's not pressed within five seconds, the gauge will automatically
save the new setting.