JAMO APS-620N Remote Starter User Manual


 
128-8613a
11 of 12
Page 11
Setting Up The System Programming Features:
Bank 1 Transmitter Channels
Start with the system disarmed, turn the ignition switch to the on position then:
1) Press and release the push button valet/program switch 3 times.
Siren Chirps once and or Lights flash one time indicating the transmitter program mode
successfully entered.
See Owners Manual for transmitter programming.
Turn the ignition switch off then on to access Bank 2 Keyless/Alarm feature selections.
1 Flash when the ignition transitions off, followed by 2 chirps/Light flashes when the key is
turned on indicates that you are in feature selection of bank 2.
Press the pushbutton switch:
1 time to access the first selection as shown below. Use the lock button of the transmit-
ter to change the feature selection or press the pushbutton to advance to the next select-
able feature.
Bank 2
Feature 1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash Default
1stDoor Lock/UL 1S/1S 3.5 S/3.5S 1 S/Dbl 1 S. Dbl 1/1 S Dbl 1/Dbl 1 1S L/350mS ul 1S/1S.
2nd Accy Lock Auto Lock On Auto Lock Off Auto Lock Off
3rd Accy. UL Auto UL On Auto UL Off Auto UL Off
4th Horn Chirp 10mS 16mS 30mS 40mS 50mS 16mS
5
th
Chp Del TX On Off Off
When finished setting the keyless/alarm selectable features, turn the ignition off then on
to advance to Bank 3, Remote Start Selectable Features.
1 Flash when the key transitions off and 3 chirps/light flashes when the key transitions on.
Press the pushbutton switch one time to access the first selection as shown below. Use
the lock button of the transmitter to change the feature selection or press the pushbutton
to advance to the next selectable feature.
Bank 3
Feature 1 Chirp/Flash 2 Chirp/Flash 3 Chirp/Flash 4 Chirp/Flash 5 Chirp/Flash 6 Chirps/Flash Default
1 RF Start Chirp Off On On
2 Run Time 5 Min. 10 Min. 15Min. 20 Min. 10 Min
3 Park Lights On Steady Flash Steady
4 Input Check Voltage Tach DBI Tach Tach
5 Voltage Level > 0.5V B4 Start < 0.5V B4 Start > 0.5
6 Ign. 2 Select Off With Crank On With Crank Same As Accy On With Crank
7 Diagnostics Off On Off
8 Crank Time 0.8Sec 1.0 Sec 1.5 Sec 2.0 Sec 1.0
9 Gas/Diesel Gas Diesel 10 Diesel 15 Diesel 20 Gas
10 Blk/Blue (Aux O/P) Single Pulse As D/L Pulse Single
11 Time Start 2 Hours 4 Hours 4 Hours