Ingersoll-Rand 650934-XX3-C Automobile Parts User Manual


 
650934-X-CPage 2 of 2
PUMP OPTION DESCRIPTION CHART
650934 - X X X - C
PACKING MATERIAL
PLUNGER TYPESPRING ARRANGEMENT
PACKING MATERIAL (packings are upper and lower unless noted)
3 Glass filled Teflon
C UHMW-PE
G UHMW-PE / Leather staggered
P UHMW-PE / Teflon staggered (upper) / UHMW-PE (lower)
R Teflon / UHMW-PE staggered (upper) / Teflon (lower)
SPRING ARRANGEMENT
4 Multiple wave spring
9 Multiple wave spring with alternate solvent cup
B Multiple wave spring with 2 piece spacer
PLUNGER TYPE
3 Hardened stainless steel with hard chrome plating
MODEL REVISION
GENERAL DESCRIPTION
WARNING
HAZARDOUS PRESSURE. Do not exceed maxi-
mum operating pressure of 2400 p.s.i. (165.5 bar) at 1200 p.s.i.
(82.8 bar) inlet hydraulic pressure.
PUMP RATIO X MAXIMUM PUMP
INLET PRESSURE TO PUMP MOTOR
= FLUID PRESSURE
Pump ratio is an expression of the relationship between the pump motor area and the
lower pump end area. EXAMPLE: When 150 p.s.i. (10.3 bar) inlet pressure is supplied
to the motor of a 5:1 ratio pump it will develop a maximum of 750 p.s.i. (52 bar) fluid pres-
sure (at no flow) - as the fluid control is opened, the flow rate will increase as the motor
cycle rate increases to keep up with the demand.
WARNING
Refer to general information sheet for additional
safety precautions and important information.
The chop-check pumps are primarily designed for the pumping of
heavy viscous material with or without fibrous content. The models
can be used with a gravity feed single post lift as a topper type as-
sembly or with a two post lift as a force feed type assembly. The low-
er pump is designed for easy priming and the double acting feature
is standard in all ARO industrial pumps. Material is delivered to the
pump discharge outlet on both the up and down stroke.
The motor is connected to the lower pump end by a spacer section.
This allows for lubrication of the upper packing gland and prevents
motor contamination because of normal wear and eventual leakage
through the material packing gland. Be sure the solvent cup is ade-
quately filled with lubricant to protect the upper packings and insure
longest service life.
TROUBLE SHOOTING
Pump problems can occur in either the hydraulic motor section or the
lower pump end section. Use these basic guidelines to help determine
which section is affected.
If the pump will not cycle.
Be certain to first check for non-pump problems including kinked, re-
strictive or plugged inlet / outlet hose or dispensing device. Depres-
surize the pump system and clean out any obstructions in the inlet /
outlet material lines.
Refer to the motor manual for trouble shooting if the pump does not
cycle and / or hydraulic fluid leaks from the hydraulic motor.
If the pump cycles but does not deliver material.
Refer to the lower pump end manual for further trouble shooting.
PUMP CONNECTION - UPPER / LOWER
NOTE: All threads are right hand.
1. Lay the pump assembly on a workbench.
2. Remove the three screws and washers from the three spacer rods
(see figure 1).
3. Pull the hydraulic motor from the lower pump end until motor piston
rod is in the down" position and lower pump end rod is in up" posi-
tion.
4. Using e-ring pliers, slide the retaining ring up far enough to allow the
sleeve to move upward and release the two connectors (see figure
2).
Lower Pump Piston Rod
Pump Motor Piston Rod
Retaining Ring 91547
Sleeve 91546
Connector 91644 (2)
PUMP CONNECTOR DETAIL
Figure 2
REASSEMBLY
1. Align the pump motor with the lower pump end.
2. Install the two connectors and retain with the sleeve, slide the retain-
ing ring back into position.
3. Reinstall the spacer rods to the pump motor.
4. Bring the motor and lower pump together and retain with the three
screws and washers.
NOTE: If 93345-1 (3) spacer rods are removed from lower end to
service lower end then torque evenly to 60 - 90 ft lbs (81.3 - 122.0
Nm).
PN 97999-835