ZDP36L6DSS - GE Monogram 36" Professional Range with 6 Burners
Dimensions and Specifications (in inches)
Advance Planning:
Refer to dimensional drawings for appropriate placement
and necessary clearances when planning
the installation.
Cabinetry cannot be installed directly above the range.
This range requires the installation of a vent hood,
30" to 36" above the surface.
The vent hood must be at least 24" deep.
The vent hood must be the same width as the range.
The vent hood must provide at least 600 CFM and
up to 800 CFM.
When installing a range that includes a grill, select a
blower on the high end of the CFM recommendation.
Working areas adjacent to the range should have
18" minimum clearance between countertop and cabinet
bottom.
Clearance between range and side wall or combustible
material must be at least 12" on each side.
If the range is installed in an island:
Allow 12" min. clearance at the back to combustible
materials.
Allow 36" min. above the cooking surface to
combustible materials.
The vent hood must provide at least 600 CFM and
up to 1200 CFM.
Installation must conform with local codes. In the
absence of local codes, the range must comply with
the National Fuel Gas Code, ANSI Z223.1-1990.
A.G.A. approved
Installation Information:
Before installing, consult installation instructions
(Pub. #49-8786) packed with product for current
dimensional data.
3/-1/4"
18" Min.
4"
35-3/8" Max. for Counter Level
36-3/4" Max. with Range Leveling Legs Fully Extended
3/-1/2"
Gas Supply
Electrical Supply
Cooking Surface
13"
Max.
4"
12"
36" Wide Range Hood
12" Min. to
Combustible
Material
Each Side
36" Min. to
Combustible
Material From
Cooking Surface
12"
Low Back
High
Shelf
29-1/16"
12"
3-1/4"
21-1/4"
12"
36" Min.
to Combustibles
28-1/4"
31-1/2"
45-5/8"
0" Clearance
Island Trim
1-1/2"
36" Min.
to Combustibles
0" Clearance
12" Min. to Combustibles
Without Backguard
R
Listed by
Underwriters
Laboratories