Furuno 1932 MARK-2 Radar Detector User Manual


 
SP - 3
Water temperature: MTW>MDA
Time: ZDA
Cross track error: RMB>XTE>APB
*1: calculate by magnetic drift.
(7) Output Data NMEA0183 (Version1.5/2.0), RS-422
TLL (target data) and RSD
5. ENVIRONMENTAL CONDITION
(1) Ambient Temperature Scanner Unit: -25°C to +70°C
Display Unit: -15°C to +55°C
(2) Relative Humidity 95 % or less at +40°C
(3) Waterproofing Scanner Unit: IPX6
Display Unit: IPX4
6. POWER SUPPLY & POWER CONSUMPTION
(1) Power Supply 12/24/32 VDC (10.8 to 41.6 VDC)
(2) Voltage and Current 24rpm: 12 VDC/7.5A, 24VDC/3.8A, 32VDC/2.8A
48rpm: 12 VDC/8.8A, 24VDC/4.4A, 32VDC/3.3A
(3) Power Consumption 24rpm: 70 W to 90 W (100 kt)
48rpm: 85 W to 105 W (70 kt)
7. DIMENSIONS AND MASS
See the Outline Drawings
8. COATING COLOR
(1) Display Unit Panel: N3.0
Chassis: 2.5GY5/1.5
(2) Scanner Unit N9.5
9. COMPASS SAFE DISTANCE
(1) M1932M2
Display Unit Standard: 1.1 m Steering: 0.8 m
Scanner Unit Standard: 1.0 m Steering: 0.8 m
(2) M1942M2
Display Unit Standard: 0.75 m Steering: 0.6 m
Scanner Unit Standard: 1.1 m Steering: 0.8 m