Ford ST2332-A Remote Starter User Manual


 
303-06-4 303-06-4Starting System
DIAGNOSIS AND TESTING (Continued)
Possible Causes
When the starter relay is energized, voltage supplied
to the relay switch is sent to the starter motor
Fuse(s)
solenoid through circuit 113 (YE/LB). Battery
An open in battery voltage feed BEC, 2037 (RD)
voltage is supplied to the starter motor through
or 113 (YE/LB)
circuit 2037 (RD) at all times.
Starter motor relay
Starter
PINPOINT TEST A: THE ENGINE DOES NOT CRANK AND THE RELAY DOES NOT CLICK
Test Step Result / Action to Take
A1 CHECK THE BATTERY
Check the battery condition and charge if necessary. Refer to
Yes
Section 414-01. GO to A2.
Is the battery OK?
No
CHARGE or INSTALL a new battery as
necessary. REFER to Section 414-01.
TEST the system for normal operation.
A2 CHECK FOR PATS DTCS
NOTE: The PATS DTCs are the only DTCs of concern in this
Yes
step. Only repair retrieved non-PATS DTCs if a customer GO to Section 419-01B to diagnose the
concern is reported. PATS DTCs.
Check for PATS DTCs.
No
Were any PATS DTCs retrieved?
GO to A3.
A3 CHECK CIRCUIT 33 (WH/PK) (CIRCUIT 32 [RD/LB] MANUAL
TRANSMISSION ONLY) FOR VOLTAGE
Disconnect: Starter Motor Relay.
Key in START position.
If equipped, fully depress the clutch pedal.
(Continued)
2005 Mustang, 12/2004