Trigger Zone Fault Report
When armed by remote command the system runs a status check
of the alarm trigger zones. Faulty zones (usually caused by dome
light delay or open trunk) are bypassed and reported via the control
center LED and remote, while all other trigger zones remain active
and are monitored to protect the vehicle. Should a faulty zone self
correct (dome light turns off) it becomes active and is then monitored
normally.
The siren chirps once again a few seconds following the arming
chirps as an audible alert, the control center LED flashes in groups to
indicate the zone number.
Alarm Report
If the alarm was triggered while armed, it will be reported when the
alarm is disarmed via the remote control, siren chirps, parking light
and control center LED flashes. The siren chirps 4 times (or 5 times if
NPC On*), the parking lights flash 3 times, and the control center LED
flashes in groups to indicate the last two zones that were triggered
(see Table of Zones). The report output will repeat for each disarm
operation until the ignition is turned on.
* See Nuisance Prevention (NPC) for more details.