CyberPower Systems CPS140BI Automobile Accessories User Manual


 
Output Power 140 Watts Continuous
Output Voltage 120Volts+/-10%
OutputFrequency 60 Hz
Output Waveform Simulated Sine Wave
Input Voltage 10.8 to 15.8 volts
LowVoltage Shutdown 10.5 volt
Problem Possible Cause Suggested Solutions
NoACoutput power
(Power indicatoris not
illuminated)
Poorcontact withlightersocket
Automotive electricalsystems
requires ignition to be on.
Car slightersocketfuseblown
Over-heating
Vehicle s battery below 10.8
volts.
Ensure the inverter adapter is securely
plugged into vehicle s lighter socket.
Replace the lighter socket if necessary.
Turnthevehicleignitionkeytothe
Accessory position.
Checkthe vehicle fuse paneland replace
the damagedfuse.
Allowinverter to cooldown. Ensurethat
there is adequate ventilation around the
unitand load is no morethan140 watts for
continuous operation.
Unplug theinverterand chargethevehicle
battery.
Short/LongBeep Yourvehicle sbatteryinput
voltage isbelowthan10.8volt.
Vehiclesbatteryinput voltage
is higher than 15.8 volt.
Inverter is overload.
Checkvehicle sbattery andensureits
capacity. Change vehicle s battery if
necessary.
Checkfor your vehicle s battery
manufacturer guideline.
Reduce loadto 140 watts max to maintain
regulation.
ContactScrew
Spring
ContactPin
Fuse
DecorativeRing
LighterAdapter
CPS140BI contains a fuse inside in the Lighter Adapter (see Figure 2) to protect the unit against
overloading. If the inverter draws more than 140 watts, the internal fuse may be blown to protect
the inverter, vehicle battery and the connected equipment. To replace the fuse, please follow the
instruction below:
1. Unplug the inverter from the power source.
2. Remove the Contact Screw from the Lighter Adapter.
3. Replace the 15 ampere fuse.
4. Reassemble the fuse, contact pin and contact screw carefully.
5. Ensure all pieces showed in Figure 2 are installed in the sequence shown.
*Note: For in-warrantyunits, thereplacementfuse canbe obtained from CyberPower
TechnicalSupport. Forout-of-warranty units, the replacement 15amperefuse canbe obtained
from most electronicsupply retailers.
WARRANTYRETURN
CyberPower Systems, Inc.
5555 12thAvenue East, Suite 110, Shakopee, MN 55379, U.S.A.
TEL: (952) 403-9500 FAX: (952) 403-0009 Toll-Free: (877) 297-6937
E-mail:sales@cyberpowersystems.com
Web: www.cyberpowersystems.com
Entire contents copyright
2004Cyber Power Systems, Inc.
Allrights reserved.Reproductionin wholeor inpartwithoutpermissionisprohibited
K01-BT14000
C
2004-5-075/back K