Avital 4501 Remote Starter User Manual


 
Programming Table for System Features
Feature
Factory
Setting
# of
Beeps
Secondary Action
Ignition-Controlled
Lock/Unlock
ON 7
Wait 3 seconds, the piezo beeper will beep
once for OFF, twice for ON
RPM Door Lock OFF 9
Wait 3 seconds, the piezo beeper will beep
once for OFF, twice for ON
Passive Starter Disable OFF 10
Wait 3 seconds, the piezo beeper will beep
once for OFF, twice for ON
Remote Lock Starter Disable ON 11
Wait 3 seconds, the piezo beeper will beep
once for OFF, twice for ON
Remote Start Run Time
20 or 30 Minutes
20
Minutes
14
Wait 3 seconds, the piezo beeper will beep
once for 30 minutes, twice for 20 minutes
Temperature-Controlled
Starting
Off or 5°F (-15°C)
OFF 16
Wait 3 seconds, the piezo beeper will beep
once for OFF, twice for 5°F (-15°C)
Temperature-Controlled
Starting
-7°F (-20°C) or -22°F (-30°C)
17
Wait 3 seconds, the piezo beeper will beep
once for -7°F (-20°C), twice for -22°F
(-30°C)
Pro gram ming Ta ble for Re mote Con trols
Feature
Factory
Setting
# of
Beeps
Secondary Action
Remote Door
Lock/Panic
C Button 18
Press the C Button, the piezo beeper will
beep 1 time
Remote Door Unlock D Button 19
Press the D Button, the piezo beeper will
beep 2 times
Remote Engine Start s Button 20
Press the s Button, the piezo beeper will
beep 3 times
Remote Trunk Release d Button 21
Press the d Button, the piezo beeper will
beep 4 times
Temperature Controlled
Start Active/Inactive
C + s
Buttons
22
Press the C + s Button, the piezo beeper
will beep 5 times
Remote Accessory
Output (-)
C + D
Buttons
23
Press the C + D Button, the piezo beeper
will beep 6 times
All Learn C Button 24
Press the C Button, the piezo beeper will
beep 1 time
Delete All 25
Wait 3 seconds, the piezo beeper will beep
twice, all codes are erased out of memory
11
AviStart 4501 Owner's Manual 0999