Diagnostics – Parking Light Flash Table
Flashes Description
1
Doors locked, starter kill armed
Run time has expired
Ι & ΙΙ buttons pressed
Start signal received by the module
Cold weather mode cancelled
2 slow flashes
followed by 8 quick
flashes
Reset from manual to automatic
2
Doors unlocked, starter kill disarmed
Remote start attempt cancelled by
remote
Exiting ignition valet
Power-up reset
Board set from manual to automatic; power
ON
Power ON to OFF (automatic transmission).
3 Entering and exiting ready mode. Entering ignition valet
4
+12 V detected on the brake input wire either while cranking or during run time
Entering multi-speed tach programming
Board set from automatic to manual; power ON
Power ON to OFF (manual transmission)
5 Fast
Tach signal programmed
New transmitter programmed
6 A remote start was attempted while a tach-before-crank signal was detected before cranking
8 Unit reset
10
A ground (-) signal was detected on the hood pin input wire when attempting to remote start or
during run time
When pressing ΙΙ
15 quick flashes…
The parking brake is connected to ground (automatic transmission)
1 – pause – 2
There was a remote start attempt while the vehicle was in valet mode
Failed start: vehicle’s low battery voltage
…followed by 1 flash Exiting cold weather mode
ON SOLID for 3
seconds….
…followed by 3 flashes Entering cold weather mode
ON continuously
Idle mode: Idle mode is engaged
Run time: The vehicle has been remote started and is in run time
ON 2 seconds The hood has been opened and a ground (-) signal has been detected on the hood pin input wire
ON 4 seconds Locking or unlocking a door (with door pulses configured to 4 sec.)
ON 20 seconds The hood pin has been flashed and you now have access to the programming options
Constantly flashin
g
up to 25 sec.
Panic mode is triggered