Audiovox PRO-9275T Remote Starter User Manual


 
128-7192
11 of 20
3 Wire Positive Switched Door Locks:
In this application, the Red wire of the door lock harness provides a + 12 volt pulse during the unlocking
sequence, or pulsed 12 volt unlock output. Connect the Red wire to the low current 12 volt signal wire from
the factory door unlock switch to the factory door unlock relay.
The Green wire of the door lock harness provides a + 12 volt pulse during the locking sequence, or pulsed
12 volt lock output. Connect the Green wire to the low current 12 volt signal wire from the factory door lock
switch to the factory door lock relay. See Below For Wiring Detail.
3 Wire Positive Switched Door Lock/Unlock Wiring Detail
Resistive Circuits, As Well As 4 Wire Polarity Reversal and 5 Wire Alternating 12 Volt
Door Lock Control Circuits
These applications require the use of additional components which may include relays, fixed resistors, or
for convenience, the AS 9159 Door Lock Interface. Refer to the AUDIOVOX Door Lock Wiring Supple-
ment and or the Audiovox fax back service for information on your particular vehicle for properly connect-
ing to these types of circuits.
2 Pin Blue Connector: Programming Switch
Route the grey and black wires in the 2 pin connector from the previously installed programming switch to
the control module and plug it into the mating blue connector on the side of the module.
WIRING THE 4 PIN AUXILIARY OUTPUT HARNESS
The auxiliary 4 pin connector provides low current outputs to control various functions in the vehicle
during different stages of the Remote Start unit's operation. Understanding these outputs and the time in
which they occur will allow you to determine if they are needed for the particular vehicle you are working
on as well as how to use them.
Black w Blue Trace Wire: Pulsed Ground Output Before Start
The Black w/ Blue Trace wire will provide a 1 second 300 mA pulsed ground output 1.5 second before the
remote start unit activates as well as when the transmitter is used to unlock the system. Typical use for
this output would be to disarm a factory theft deterrent system to prevent false triggering of the factory
alarm when the remote start unit engages or when the APS-675 is used to unlock the doors.
Black w/ Light Green Trace Wire: Pulsed Ground Output After Start
The Black w/ Light Green Trace wire will provide a 1 second mA pulsed ground output after the vehicle is
started under control of the remote start unit. Typically this wire will be used to re-lock the vehicle doors if
the doors unlock automatically when the factory anti-theft system is disarmed.
Black w/ Red Trace Wire: Pulsed Ground Output After Shutdown
The Black w/ Red Trace wire will provide a 1 second 300 mA pulsed ground output after the remote start
unit shuts down. This output will occur regardless of whether the circuit times out or is manually termi-
nated. Typically this output will be used to re-lock the vehicle doors if the doors unlock automatically
when the ignition circuit transitions to off.
11