Custom Code Programming Example:
To Change the code from the factory pre-assigned code of 11 to “52” you would do the
following:
1. Disarm the system by use of the transmitter, or by use of the emergency override
sequence.
2. Turn the ignition switch to the on position.
3. Within 10 seconds, press and release the PBLED switch, 3 times.
4. Within 10 seconds turn the ignition switch off, on, off, on, off, on.
(The siren or horn will beep and the lights will flash one time.)
5. Within 10 seconds, begin to press and release the PBLED switch to set the tenths digit.
(As per the example, press and release 5 times to set the tenths digit to 5)
6. Within 10 seconds of the last press of the pushbutton, turn the ignition switch off then on.
7. Within 10 seconds, begin to press and release the PBLED switch to set the units digit.
(As per the example, press and release 2 times to set the units digit to 2).
8. Turn the ignition switch to the off position. Immediately observe the LED flash pattern.
You will note the LED flashing five times, pause, and then flash two times, pause. This pattern will be
repeated three times indicating the new code (52) has been accepted and stored in memory.
NOTE: If after step 7, the LED flashes a code other than what was just entered, this
indicates that the code has not been changed. You will have to repeat steps 1
through 7 above being certain to note the following:
Acceptable digits 10ths or units are 1 through 9. The unit will not recognize a 0 (Zero), or no
digit entered in any place, units or tenths.
NOTE: If 15 seconds of inactivity expire, or if the ignition switch is turned off for more then 5 seconds
during any of the above steps, the unit will revert back to the last successfully stored code.
MANUALLY OVERRIDING YOUR SYSTEM:
USING THE CUSTOM CODE OVERRIDE
Assuming the override code programmed has not been changed, and the default override
code of 11 is in the system's memory.
1) Enter the vehicle and turn the ignition switch to the on position.
NOTE: The siren will sound.
2) Within 5 seconds, press and release the PBLED switch 1 time.
3) Within 5 seconds, turn the ignition switch off then on.
4) Within 5 seconds, press and release the PBLED switch 1 time.
5) Turn the ignition switch off then on and start the vehicle.
NOTE: If you have changed the programmed override code then substitute your new code
tenths for step 2 above, and units for step 5 above.
ELIMINATING THE NORMAL ARM/DISARM CHIRPS
You can selectively eliminate the normal arm & disarm chirps by holding the transmitter button
slightly longer when arming or disarming. This will prevent the siren chirps for one arm or
disarm cycle. If you find this inconvenient and wish to eliminate these chirps permanently,
1. Turn the ignition switch 'on" then 'off".
3. Within 10 seconds of turning off the ignition, press and release the PBLED switch 3 times.
4. If the chirps were on before you started, the siren will emit 2 short chirps indicating that
the chirps are now off. If the chirps were off before you started, the siren will emit one
short chirp indicating that the chirps are now on.
NOTE: If the vehicle battery is disconnected then reconnected, the unit will return to the
default setting of chirps on. Repeat the above procedure to eliminate the arm/disarm
chirps.