Ultra Start 450 SERIES Automobile Alarm User Manual


 
SHOCK SENSOR ADJUSTMENTS
3 CHIRPS
Press & HOLD Lock + Unlock buttons at the same time
Press & HOLD Lock + Unlock buttons at the same time
(NOTE: Shock Sensor Adjustment Mode has an auto time out of
8 seconds)
Each time the lock button is pressed and released the sensitivity will
decrease by 1 level.
This is confirmed by a series of park light flashes & Siren Chirps
1 Flash / Chirp is the least sensitive setting
10 Flashes / Chirps is the most sensitive setting
Each time the unlock button is pressed and released the sensitivity will
increase by 1 level.
This is confirmed by a series of park light flashes & Siren Chirps
1 Flash / Chirp is the least sensitive setting
10 Flashes / Chirps is the most sensitive setting
Continue to hold for 3-5 seconds Until Siren Chirps 3 times
(Note: System will Arm or Disarm via silent arming prior to
entering adjustment mode)
1 - ENTER SHOCK SENSOR ADJUSTMENT MODE
2 - ADJUSTING SENSOR
3 - EXITING SENSOR ADJUSTMENT MODE
+
+
ALARM STATUS / DIAGNOSTICS
ALARM STATUS / DIAGNOSTICS
SIREN CHIRPS LED FLASHES DIAGNOSTICS / STATUS
3 2 SHOCK SENSOR TRIGGER
3 3 DOOR / HOOD TRIGGER
3 4 IGNITION TRIGGER
0 OFF SYSTEM DISARMED
0 ON SOLID SYSTEM IN VALET / SERVICE MODE
0 SINGLE FLASHES SYSTEM ARMED
0 RAPID FLASHES PASSIVE ARM COUNTDOWN
LED FLASHES OUTPUT DIAGNOSTICS
2 LOCK OUTPUT OVERLOAD
3 UNLOCK OUTPUT OVERLOAD
4 TRUNK OUTPUT OVERLOAD
5 STARTER DISABLE OVERLOAD
6 NOT USED
7 AUX 5 OUTPUT OVERLOAD
8 2ND UNLOCK OUTPUT OVERLOAD
If the alarm system is triggered, the system will retain in memory the cause of the
trigger. When disarming the alarm, the siren/horn will chirp 3 times to indicate
the alarm had been triggered. The system’s LED will also flash in pulses to
indicate which input triggered the alarm.
*LED status will be cleared when the ignition is turned ON. For proper memory
clearing, insure to connect the alarm ignition input to the ignition on the vehicle.
If an output from the alarm is shorted the siren will chirp 4 times and the park
lights will flash 4 times when the system is armed or disarmed. The LED will flash
a diagnostic code that represents the circuit that is at fault. (See Chart Below).
Turning the ignition to the on then off position will reset the diagnostic code.
ADDITIONAL LED FUNCTIONS
While the system is disarmed and the ignition is in the off position, the
LEDs will activate from the following triggers.
1) If the door is opened the LEDs will stay on until the door is closed.
2) If the hood is opened the LEDs will stay on until the hood is closed.
3) If the shock sensor detects vibration the LEDs will turn on momentarily.
4) If the auxiliary sensor input is activated the LEDs will activate momentary.
SYSTEM PROGRAMMING - Menu 1
SYSTEM PROGRAMMING - Menu 1
PAGE 10
PAGE 11
450 SERIES
450 SERIES
OWNER'S MANUAL
OWNER'S MANUAL
SHOCK SENSOR
DIAGNOSTICS