Antari Lighting and Effects W-508 Automobile Accessories User Manual


 
Addressing
Each machine occupies 1 channel. To ensure that the control signals are
properly directed to the machine, it requires addressing. If several machines
are used, each machine must be addressed by changing the DIP switches as set
out in the table below.
The starting address is defined as the first channel from which the machine will
respond to the controller.
Please make sure that you do not have any overlapping channels in order to
control each machine correctly and independently from any other fixture on the
DMX data link. If two, three or more devices are addressed similarly, they will
work similarly.
Occupation of the DIP switches:
Performance Note
All fog machines develop condensation around the output nozzle. Because this
may result in some moisture accumulation on the surface below the output
nozzle, consider this condensation when installing your unit.
All fog machines may sputter small amounts of fog occasionally during
operation and for a minute or so after being turned off.
All fog machines have a recycling period after long bursts when the machine
will shut itself down for a short period in order to heat up again. During this
time no fog can be produced.
Setting the DMX-
starting address:
DIP-switch no.
Device number
& channels
Starting address
Device 1 - Channel 1
ON
OFF
1
1
2
2
3
4
4
8
5
16
6
32
7
64
8
128
9
256
Device 2 - Channel 2
ON
OFF
Device 3 - Channel 3
ON
OFF
Device 4 - Channel 4
ON
OFF
Device 5 - Channel 5
ON
OFF
-08-