a single controller for parallel control of an unlimited number of machines. Just power
on the machines simultaneously and register the controller. If there is no wireless
controller registered in wireless setup mode, the machine will keep the record of the
previous operation.
In order to register a wireless controller press button A or B. Always direct the
controller towards the receiver underneath the display. When the registration process
is started, a beeping sound will occur followed by a flashing display. After 15 seconds,
the machine exits the wireless setup mode and the display indicates “Wireless Setup
OK”. At this point, no further controller can be added. Then the fog machine starts with
the warm-up process and the display indicates “Warming Up”.
4. The warm-up time takes around 9.5 minutes. While the unit is warming up, fog output
will not be possible yet. Once the warm-up process is completed, the display will
indicate “Ready To Fog” and additionally a “W” for wireless if this function is activated.
Afterwards, the liquid sucking process is indicated on the display. During the initial
start-up, there will repeatedly be air in the liquid pipe that prevents the machine's
sensor from detecting the fog liquid. In this case, the display will indicate Empty
Fluid”. Please press the button VOLUME at the control panel, in order to force the
machine to draw the liquid from the tank. During this pumping process, the motor will
make a “Bo Bo Bo” noise, which is a normal reaction. Before the sensor can detect the
fluid, the display will switch between “Ready To Fog W” and “Empty Fluid”.
Operation
The built-in control panel on the rear of the machine features an LCD panel displaying all
operation statuses of the fog machine. The control panel allows the user to customize fog
machine functions by adjusting the fogging duration, interval, and volume as well as the
DMX address and the wireless function. There are four buttons on the control board. All
current operating parameters are automatically stored in non-volatile memory, allowing the
machine to be powered down without losing function settings.
Control buttons:
Function / Up / Down / Stop
After warming up and sufficient fluid intake, the display will indicate “Ready To Fog W” and
fog output will be possible. You can now program the necessary menu settings with the