A SERVICE OF

logo

5
Level
The vial bubble (8) is precisely centered, using the vertical setting dial (3)
II. Aligning the laser dot horizontally (left - right):
Mark the horizontal position on the second joist / stud. (No need to measure
the vertical position). Turn on the laser(2). Dial the laser beam onto the mark
by using the horizontal setting dial (4).
ATTENTION :
To ensure that the HL 100 is set up to point in the right direction, it is
important that the lay out and drilling of the first joist/stud , as well as the
horizontal measurement on the second joist/stud is done accurately.
III. Aligning the laser dot vertically (up - down):
Slope
The vial's ring markings (8) allow the laser dot to be adjusted to an inclination,
up or down, of approximately 1% or 2%. Move the vial bubble accordingly by
using the vertical setting dial (3)
∆ = 1 %
ft
∆ = 2 %
1 “
8
ft
1 “
4