StarKeeper II NMS
Configuration of the StarKeeper II NMS
b . Choose SYSADM ; this displays the Sysadm menu
c . Choose SHUTSK; select y to continue with shutdown. Enter
Return when you see the shutdown completed message.
d . Exit the SKsh program by pressing Return and then y at the
Exit the Menu Program? prompt.
3 . At the SK: prompt, enter the su command with no arguments to change
your user id to root.
4 . Confirm that the StarKeeper II NMS Support for LCS60 for Ethernet package
has not been previously installed on this StarKeeper II NMS. At the #
prompt enter the /usr/bin/displaypkg command (6386) or the cat -s
$INPUT/L60.name command (HP 720/730). If the output of the com-
mand entered does not contain a line that begins with: SK II NMS L60
Utility: R3.0 proceed to Step 5. If the command output does contain
the above line then the StarKeeper II NMS Support for LCS60 for Ethernet
package installed on this StarKeeper II NMS must be removed before the
new package can be installed.
Note: If you have a version of the StarKeeper II NMS Support for LCS60
for Ethernet package currently installed you must remove it now.
To remove it:
a . Have on hand the diskette or tape that was originally used to
install the current package.
b . Follow the appropriate instructions for your hardware:
For 6386
Hardware
At the # prompt, enter the /usr/bin/removepkg
command and respond to the prompts.
For HP
Hardware
Insert the tape into the tape drive and wait until
the light stops blinking. Then execute the follow-
ing four commands at the # prompt:
B-2 Issue 3