MFP disassembly/assembly
9 Remove two screws to remove the
conveyance unit.
10 Disconnect the three connectors
(CN421, 426, 427).
CAUTION Each inline connector
consists of two male sides
and one female side. Be
sure to remove only the
male side (shown below) of
the connector.
11 Remove two screws to remove the
harness guide plate (front).
12 Remove four screws to detach the
registration drive motor assembly.
High voltage
supply unit (1)
Screws
Relay connector
(CN460)
Relay
connector
(CN461)
Conveyance
unit
Screw
Relay connector
(CN427)
Harness guide plate
(front)
Screw
Screw
Relay connector
(CN426)
Relay connector
(CN421)
Registration drive motor assembly
Screw
Screws(3)