PART NO. 37-6658D
Replaces 37-6658C
0927
36H UNIVERSAL GAS VALVES
FIELD
CONVERSION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
DESCRIPTION
The 36H universal gas valves are designed for use on automatic
spark ignition systems. The valves are shipped from the factory
set for natural gas non-piloted applications. See the Installation
Instructions included with the valves for proper installation.
This document shows the modications required if the valve is
to be installed on an LP gas and/or piloted gas application.
LP GAS CONVERSION
For LP gas conversion, use the LP conversion kit supplied
separately with this control. Refer to the instructions packed
separately with LP conversion kit.
PILOTED GAS APPLICATIONS
WIRING
These valves are shipped with an external wire jumper installed
for non-piloted gas applications. For applications requiring piloted
gas, such as intermittent pilot or spark-to-pilot systems, remove
the external wire jumper from the main (M) and pilot (P) valve
terminals (see gure 1).
Refer to the 36H Series Installation Instructions for additional
system wiring information.
PILOT GAS CONNECTION
These gas valves are shipped with the pilot outlet plugged. For
installations requiring pilot gas, remove the plug from the pilot
gas outlet (see gure 2) and use the tting packed separately
with the valve.
Install the tting into the pilot gas outlet, turning until nger tight.
Insert clean, de-burred ¼” O.D. tubing all the way through the
tting. While holding the tubing securely, slowly tighten the t-
ting until you feel a slight “give”. Tighten the tting an additional
1-1/2 turns.
The plug should not be removed for a Direct Burner Ignition
system such as Direct Spark or Hot Surface Ignition.
Refer to the 36H Series Installation Instructions for pilot ame
adjustment information.
Pilot Gas
Outlet
Outlet
Pressure
Ta p
Main Gas
Outlet
Figure 2. Gas valve outlet end
Model No. Opening
No. of Stages Characteristics
36H32-XXX 1 Fast
36H33-XXX 1 Slow
36H64-XXX 2 Fast
36H65-XXX 2 Slow
PILOT (REDUNDANT)
EXTERNAL
JUMPER
2ND
STAGE
TWO STAGE
MODELS ONLY
(+)
(-)
SW1
SW1
SW2
P
MAIN
C
SW2
RECTIFIER
(-)
RECTIFIER
(+)
M
RECTIFIER
(-)
(+)
HI
Figure 1. Gas valve internal wiring and terminal
identification
The Emerson logo is a
trademark and a service mark
of Emerson Electric Co.