Raymarine hsb2 PLUS Series GPS Receiver User Manual


 
7-12 hsb
2
PLUS Series LCD Display
Radar Set Up
Parameters
7.4 Radar Set Up Parameters
The RADAR SET UP option allows you to set up the radar according to your
system configuration and your personal preferences.
Note: Some parameters can only be changed if you are using the Master dis-
play (that is, the display to which the scanner is connected).
The following table lists the Radar Set Up parameters and their options,
shows the factory default setting, and provides a space for you to make a
note of your new default setting. Each parameter is described in the fol-
lowing subsections.
EBL Display
The mode of the bearing data displayed for Electronic Bearing Lines
(EBLs). The bearing information can be displayed in either of two forms:
Relative: The bearing relative to your vessel’s heading.
Mag/True: The actual bearing in either degrees magnetic or degrees true.
This option is only available if you are obtaining data from a compass.
If you choose this mode, the selection you made for Bearing Mode
determines whether °M or °T is displayed in the EBL data boxes. The
current units are shown for the heading value in the status bar at the top
of the screen.
Table 7-2: Radar Set Up Parameters
Parameter Options Factory Default New Default
EBL DISPLAY MAG/TRUE, RELATIVE RELATIVE
TIMED
TRANSMIT
OFF, ON OFF
TRANSMIT PERIOD 10 scans, 20 scans, 30 scans 20 scans
STANDBY PERIOD 3, 5, 10 or 15 mins 10 minutes
DEFAULT MARK
SYMBOL , , ,
MARK DISPLAY OFF, ON ON
CLEAR MARKS Press soft key to clear marks
database
N/A
CUSTOM SCALE OFF, ON,SET RANGES... OFF
BEARING
ALIGNMENT
Slider value 0°
ANTENNA SIZE 4 ft., 6ft (only if an open array
scanner is connected)
4 ft.
SEND ON HSB ON, OFF ON
81186_3.book Page 12 Thursday, August 22, 2002 8:23 AM