Raymarine autopilot control unit GPS Receiver User Manual


 
78 ST7001+ Autopilot Control Unit - Owners Handbook
7 Adjusting Autopilot Settings
Accessing the Calibration mode
You can only access Calibration mode from Standby mode:
1. With the autopilot in Standby mode, press and hold the
standby
key for 2 seconds. The display will change to show
DISPLAY CAL.
2. Press the
disp key or down arrow key to scroll down through the
4 calibration groupings:
Display Calibration
(DISPLAY CAL)
User Calibration
(USER CAL)
Seatrial Calibration
(SEATRIAL CAL)
Dealer Calibration
(DEALER CAL)
Note: You can go backwards through the groups by pressing and
holding the
disp key for one second or by using the up arrow key.
3. When you reach the Calibration group you want to access, press
the
auto key to enter that group:
To prevent accidental access, we have made entry to Dealer
Calibration more difficult than the other groups. After pressing
the
auto key, the display will show CAL. When you see this, press
the
-1 and +1 keys together to enter Dealer Calibration.
4. When you have entered one of the Calibration groupings, press
disp key or down arrow key to scroll down through the items
within that grouping:
Note: You can go backwards through the list by pressing and holding
the
disp key for one second or by using the up arrow key.
5. When you reach an item you wish to adjust, use the
-1, +1, -10 and
+10 keys (as appropriate) to change the value.
6. If you then want to adjust settings in another Calibration group,
press the
standby key and then repeat steps 2 to 5 as necessary.
7. When you have made all the changes you want to make, press and
hold the
standby key for two seconds to exit Calibration mode
and save changes.