Crusader PowerView Instruction Sheet
INITIAL TWIN ENGINE SET UP
1.
After installation start your engines. Both PowerView
units will be reading the Master engine. Choose to leave
one engine running and kill the other.
2.
While the one engine is running, press MENU on the
PowerView keypad. Scroll down to the bottom of the
second page until UTILITIES is highlighted. Press
Enter.
3.
Within the UTILITIES menu you will find a list of options.
4.
Scroll to the bottom of the second page until “SELECT
ENGINE ECU” is highlighted. Press ENTER.
5.
This screen will default to listen to the Master engine (0).
To change this to listen to the Slave engine (1) press the
right arrow key. 1 will appear on the screen. Press
ENTER.
NOTE:
Make sure to press ENTER after selecting ECU
1 in order to activate your selection.
6.
Press MENU to go back to the main data screens. You
should now have data available for the engine. If you do
not, then the engine you are working with is the Master
and should be set to 0 and the other engine is the Slave
and should be set to 1. Repeat this process to change
the other PowerView unit.